Installation of facade panels
Installation of facade panels – maybe the most important step in renovating your booth. In case of correct installation, lay not only the old look, but also the protection of the main material, but also a guarantee. Let's hope that 50 years of service can be secured only with the correct installation of facade panels. It's a pity, deyakі vlasniki budinkov, trying to save, entrust the installation to non-professional workers, as it is often necessary not to read the recommendations we have specially provided for the installation of facade panels. As a result – thermal gaps are not secured, tightly screwed to the facade of the panel, so that they cannot expand and sound under the influence of temperatures. One of the widest pardons during the installation of facade panels is the lack of grating.
Once again, we give you respect! Installation of wall panels – an important stage of work over your booth. Please read the installation instructions carefully. Victory the original profiles and the recommended tool and materials.
Regardless of those that the installation of panels does not require special skills, we recommend using the services of professionals.
Preparation of surface walls before installation and installation of lathing
Facade panels Döcke-R can be installed at any time of the year, with a hint of severe frost (temperature below -15C). The panels are installed on the future, on the walls, on the sporadzhuvanny, awakened and long-term exploitation of the walls. All facade work can be completed on the cob assembling facade panels.
Install windproofing, as it was transferred by the project. If you are planning to install additional thermal insulation, install additional insulation under insulation. The sheathing under the facade panels can be made of wood (for which type it is necessary to make it in advance with special biological warehouses) or special galvanized profiles, which are used for facade work. Lathing is installed vertically/horizontally. Horizontal gratings are installed under the starting profile, J-profile, horizontal mounting points for panels. The vertical lathing is installed under the cut and the vertical place of the panel fastening. The crochet of the lathing is visible, moving out of the expansion of the panels that are being installed. The entire grating is installed to ensure the smooth surface.
Basic rules for installation
Because facade panels can expand and contract when the temperature changes, during installation it is necessary to observe the following rules:
- screws are screwed strictly horizontally in the center of the flower opening;
- Fix a small gap between the screw cap and the panel/profile (no more than 1 mm);
- insert one panel into the slot until it stops, as a guarantee of a thermal gap;
- installation is carried out at a temperature not lower than -15C.
Installing the starting profile
In order to proceed with the installation of the panels, it is necessary to make the basement "in good condition" by marking the lowest point of the wall above the horizon. You can do it for the help of the water line. Since the water is in a horizontal position, designate it as an olive on the wall. So shy away from the skin of life, bypassing yoga around the perimeter. You are guilty to come to the very point where you started. In the presence of olive mites, they win up to the bottom of the wall.
Yakshcho vydstanov vіd mіtok to zemlі rіzna – the foundation of the spreading is nervous. In this way, with small chins, more paving is better, in parallel, earlier in the horizontal line and mounting the starting profiles, as it was described above. Even though it is impossible to do so, it is necessary for the starting profile in these places to fall. Therefore, it is necessary to designate another row of panels at a higher height.
Determine the required size and dry the lower parts of the panels to the required size. Install them, fixing them at the upper horizontal and vertical tabs. If necessary, you can open additional flowers similar to the factory ones at the bottom of the panels. It’s better to work in the “seam” sections, so that the screw is less commemorative.
Respect! It is not possible to fasten the panel with a screw with a path, screwing it in the middle in the panel (with a flowered lapel), shards can be brought to the deformation of the viroba over time.
Installation of the universal J-profile
Version of the facade J-profile in the design of the internal duct:
- Prepare two façade J-profiles of the necessary interior, install them at the inner corner of the room.
- Insert a screw at the upper part of the upper flower opening, other screws are installed in the center of the flower openings. The size of the installation can be 150-200 mm.
Changing the facade J-profile as edging the upper part of the panels: - To complete the installation of the panels, fasten the facade J-profile on the battens at the top installation point (at the time of the pediment at – under the sound of cover).
- Close the facade J-profile by analogy with installation
x of the winning elements of the system. To start a universal J-profile panel, you can do it.
Installing facade panels Döcke-R
Installing facade panels
In order to optimally refinish the top of the first panel and the rest of the row, trim the front of the front. Cut the left part of the panel under a straight cut, having obtained the panel of the required size. Install the lower part of the panel on the starting profile and fasten it with screws in the flower openings. The advancing panel is installed on the starting profile in the same way as the first one; Fix a panel on the grate to a friend. The foot panels are installed in the same way. Trim the remaining panel to the extent necessary for the completion of the row, fasten the upper part of the remaining panel with screws. After completing the installation of the first row, proceed to the next row of panels. Installation of another row is similar to the first one.
Respect! To remove the natural look of stone or stone masonry, replace the skin step row of BERG panels (ground stone masonry) by one strand, and the skin step of the low BURG and STEIN panels by a sufficient amount.
For ease of installation, back up the back of the end panel. It’s not the fault of a smaller than 20 cm. When installing the rest of the row, it’s enough to insert the upper part of the panels into the facade J-profile and fasten the panels at the vertically stitched flowers open.